Envelope interchange · 4.17×7.48 in

106×190 mm filter elements

10 elements from 4 brand(s) share this envelope: 106 mm outside diameter and 190 mm overall length (4.17×7.48 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
HD1070 MANN-FILTER 72 — — — housing — inline
RA-170-E-03-B STAUFF 72 — — — housing — inline
RA-170-E-05-B STAUFF 72 — — — housing — inline
RA-170-E-10-B STAUFF 72 — — — housing — inline
RA-170-E-20-B STAUFF 72 — — — housing — inline
RA-170-L-10-B STAUFF 72 — — — housing — inline
HF29239 Fleetguard 10.4 — 20.7 µm at β200(c); 26.6 µm at β1000(c) per ISO 16889 — housing — inline
HF6308 Fleetguard 72 57 57 µm at β75(c) per ISO 16889 8 housing — inline
HF7959 Fleetguard 72 10 10 µm at β75(c); 11 µm at β200(c) per ISO 16889 8 housing — inline
R3.1119-06K1 ARGO-HYTOS 72 10 — 10 housing — inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 106×190 mm filter elements interchangeable?
They share the same physical envelope — 106 mm OD and 190 mm length (4.17×7.48 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 10 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 106×190 mm in inches?
106×190 mm converts to approximately 4.17×7.48 in.

Browse all 106 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.