Envelope interchange · 4.49×16.30 in

114×414 mm filter elements

92 elements from 4 brand(s) share this envelope: 114 mm outside diameter and 414 mm overall length (4.49×16.30 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
0850 R 003 ON HYDAC 68 3 ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000) 20 2.96 bar Nitrile (Buna-N) return
0850 R 003 ON /-B6 HYDAC 68 3 ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000) 20 6 bar Nitrile (Buna-N) return
0850 R 003 ON /-KB HYDAC 68 3 ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000) 20 housing Nitrile (Buna-N) return
0850 R 003 ON /-V HYDAC 68 3 ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000) 20 2.96 bar Fluorocarbon (Viton) return
0850 R 005 ECON2 HYDAC 68 5 ßx(c) ≥ 1000 (HYDAC grade convention: β7(c) ≥ 1000) 10 2.96 bar Nitrile (Buna-N) return
0850 R 005 ECON2 /-KB HYDAC 68 5 ßx(c) ≥ 1000 (HYDAC grade convention: β7(c) ≥ 1000) 10 housing Nitrile (Buna-N) return
0850 R 005 ON HYDAC 68 5 ßx(c) ≥ 1000 (HYDAC grade convention: β7(c) ≥ 1000) 20 2.96 bar Nitrile (Buna-N) return
0850 R 005 ON /-B1 HYDAC 68 5 ßx(c) ≥ 1000 (HYDAC grade convention: β7(c) ≥ 1000) 20 1 bar Nitrile (Buna-N) return
0850 R 005 ON /-B6 HYDAC 68 5 ßx(c) ≥ 1000 (HYDAC grade convention: β7(c) ≥ 1000) 20 6 bar Nitrile (Buna-N) return
0850 R 005 ON /-KB HYDAC 68 5 ßx(c) ≥ 1000 (HYDAC grade convention: β7(c) ≥ 1000) 20 housing Nitrile (Buna-N) return
0850 R 010 BN4AM HYDAC 68 10 β10 > 200 (HYDAC grade convention: β12(c) ≥ 1000) 20 2.96 bar Nitrile (Buna-N) return
0850 R 010 ON HYDAC 68 10 ßx(c) ≥ 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 2.96 bar Nitrile (Buna-N) return
0850 R 010 ON /-B1 HYDAC 68 10 ßx(c) ≥ 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 1 bar Nitrile (Buna-N) return
0850 R 010 ON /-B6 HYDAC 68 10 ßx(c) ≥ 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 6 bar Nitrile (Buna-N) return
0850 R 010 ON /-KB HYDAC 68 10 ßx(c) ≥ 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 housing Nitrile (Buna-N) return
0850 R 010 ON /-SFREE HYDAC 68 10 ßx(c) ≥ 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 2.96 bar — return
0850 R 010 ON/PO / -KB HYDAC 68 10 ßx(c) ≥ 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 housing Nitrile (Buna-N) return
0850 R 010 P/HC HYDAC 68 10 β12(c) ≥ 1000 per ISO 16889 10 2.96 bar Nitrile (Buna-N) return
0850 R 010 P/HC /-B1 HYDAC 68 10 β12(c) ≥ 1000 per ISO 16889 10 1 bar Nitrile (Buna-N) return
0850 R 015 MM HYDAC 68 15 β18 > 200 10 2.96 bar Nitrile (Buna-N) return
0850 R 020 MM /-KB-S/W HYDAC 68 20 β20 > 200 (HYDAC grade convention: β22(c) ≥ 1000) 10 housing Nitrile (Buna-N) return
0850 R 020 ON HYDAC 68 20 ßx(c) ≥ 1000 (HYDAC grade convention: β22(c) ≥ 1000) 20 2.96 bar Nitrile (Buna-N) return
0850 R 020 ON /-B1 HYDAC 68 20 ßx(c) ≥ 1000 (HYDAC grade convention: β22(c) ≥ 1000) 20 1 bar Nitrile (Buna-N) return
0850 R 020 ON /-B6 HYDAC 68 20 ßx(c) ≥ 1000 (HYDAC grade convention: β22(c) ≥ 1000) 20 6 bar Nitrile (Buna-N) return
0850 R 020 ON /-KB HYDAC 68 20 ßx(c) ≥ 1000 (HYDAC grade convention: β22(c) ≥ 1000) 20 housing Nitrile (Buna-N) return
0850 R 020 ON/PO /-KB HYDAC 68 20 ßx(c) ≥ 1000 (HYDAC grade convention: β22(c) ≥ 1000) 20 housing Nitrile (Buna-N) return
0850 R 020 P/HC HYDAC 68 20 β22(c) ≥ 1000 per ISO 16889 10 2.96 bar Nitrile (Buna-N) return
0850 R 020 P/HC /-V HYDAC 68 20 β22(c) ≥ 1000 per ISO 16889 10 2.96 bar Fluorocarbon (Viton) return
0850 R 025 W /-KB HYDAC 68 25 — 20 housing Nitrile (Buna-N) return
0850 R 025 W/HC HYDAC 68 25 — 20 2.96 bar Nitrile (Buna-N) return
0850 R 025 W/HC /-KB HYDAC 68 25 — 20 housing Nitrile (Buna-N) return
0850 R 040 AM HYDAC 68 40 β40 > 30 10 2.96 bar Nitrile (Buna-N) return
0850 R 050 W/HC HYDAC 68 50 — 20 2.96 bar Nitrile (Buna-N) return
0850 R 074 W/HC HYDAC 68 74 — 20 2.96 bar Nitrile (Buna-N) return
0850 R 074 W/HC /-B0.2 HYDAC 68 74 — 20 0.21 bar Nitrile (Buna-N) return
0850 R 074 W/HC /-B1 HYDAC 68 74 — 20 1 bar Nitrile (Buna-N) return
0850 R 074 W/HC /-B6 HYDAC 68 74 — 20 6 bar Nitrile (Buna-N) return
0850 R 074 W/HC /-KB HYDAC 68 74 — 20 housing Nitrile (Buna-N) return
0850 R 100 W/HC HYDAC 68 100 — 20 2.96 bar Nitrile (Buna-N) return
0850 R 100 W/HC /-KB HYDAC 68 100 — 20 housing Nitrile (Buna-N) return
0850 R 149 W/HC HYDAC 68 149 — 20 2.96 bar Nitrile (Buna-N) return
0850 R 149 W/HC /-B6 HYDAC 68 149 — 20 6 bar Nitrile (Buna-N) return
0850 R 149 W/HC /-KB HYDAC 68 149 — 20 housing Nitrile (Buna-N) return
HD12112 MANN-FILTER 68 — — — housing — inline
HD12112/1 MANN-FILTER 40 — — — housing — inline
RE-200-G-03-B STAUFF 68.2 — — — housing — inline
RE-200-G-03-B-B6.0 STAUFF 68.2 — — — housing — inline
RE-200-G-03-B-NB STAUFF 68.2 — — — housing — inline
RE-200-G-03-V STAUFF 68.2 — — — housing — inline
RE-200-G-03-V-B6.0 STAUFF 68.2 — — — housing — inline
RE-200-G-03-V-NB STAUFF 68.2 — — — housing — inline
RE-200-G-05-B STAUFF 68.2 — — — housing — inline
RE-200-G-05-B-B1.0 STAUFF 68.2 — — — housing — inline
RE-200-G-05-B-B6.0 STAUFF 68.2 — — — housing — inline
RE-200-G-05-B-NB STAUFF 68.2 — — — housing — inline
RE-200-G-05-V STAUFF 68.2 — — — housing — inline
RE-200-G-05-V-B6.0 STAUFF 68.2 — — — housing — inline
RE-200-G-05-V-NB STAUFF 68.2 — — — housing — inline
RE-200-G-10-B STAUFF 68.2 — — — housing — inline
RE-200-G-10-B-B1.0 STAUFF 68.2 — — — housing — inline
RE-200-G-10-B-B6.0 STAUFF 68.2 — — — housing — inline
RE-200-G-10-B-NB STAUFF 68.2 — — — housing — inline
RE-200-G-10-V STAUFF 68.2 — — — housing — inline
RE-200-G-10-V-B6.0 STAUFF 68.2 — — — housing — inline
RE-200-G-10-V-NB STAUFF 68.2 — — — housing — inline
RE-200-G-20-B STAUFF 68.2 — — — housing — inline
RE-200-G-20-B-B1.0 STAUFF 68.2 — — — housing — inline
RE-200-G-20-B-B6.0 STAUFF 68.2 — — — housing — inline
RE-200-G-20-B-NB STAUFF 68.2 — — — housing — inline
RE-200-G-20-V STAUFF 68.2 — — — housing — inline
RE-200-G-20-V-B6.0 STAUFF 68.2 — — — housing — inline
RE-200-G-20-V-NB STAUFF 68.2 — — — housing — inline
RE-200-GP-10-B-NB STAUFF 68.2 — — — housing — inline
RE-200-GP-20-V-NB STAUFF 68.2 — — — housing — inline
RE-200-N-10-V STAUFF 68.2 — — — housing — inline
RE-200-N-20-B-NB STAUFF 68.2 — — — housing — inline
RE-200-N-20-V STAUFF 68.2 — — — housing — inline
RE-200-S-100-B STAUFF 68.2 — — — housing — inline
RE-200-S-100-B-NB STAUFF 68.2 — — — housing — inline
RE-200-S-200-B STAUFF 68.2 — — — housing — inline
RE-200-S-25-B STAUFF 68.2 — — — housing — inline
RE-200-S-25-B-NB STAUFF 68.2 — — — housing — inline
RE-200-S-25-V STAUFF 68.2 — — — housing — inline
RE-200-S-25-V-NB STAUFF 68.2 — — — housing — inline
RE-200-S-50-B STAUFF 68.2 — — — housing — inline
RE-200-S-50-B-B1.0 STAUFF 68.2 — — — housing — inline
RE-200-S-50-B-B6.0 STAUFF 68.2 — — — housing — inline
RE-200-S-50-B-NB STAUFF 68.2 — — — housing — inline
RE-200-S-50-V STAUFF 68.2 — — — housing — inline
RE-200-S-50-V-B6.0 STAUFF 68.2 — — — housing — inline
RE-200-S-50-V-NB STAUFF 68.2 — — — housing — inline
HF6852 Fleetguard 68.2 6 6 µm at β75(c); 8 µm at β200(c) per ISO 16889 30 housing — inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 114×414 mm filter elements interchangeable?
They share the same physical envelope — 114 mm OD and 414 mm length (4.49×16.30 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 92 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 114×414 mm in inches?
114×414 mm converts to approximately 4.49×16.30 in.

Browse all 114 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.