Envelope interchange · 1.81×5.28 in

46×134 mm filter elements

21 elements from 1 brand(s) share this envelope: 46 mm outside diameter and 134 mm overall length (1.81×5.28 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
N10 Schroeder Industries 20 10 18 µm at β(c) ≥ 200 (99.5% efficiency) 10.3 housing Nitrile (Buna-N) inline
N25 Schroeder Industries 20 25 β(c) ≥ 1000 (99.5% efficiency) 10.3 housing Nitrile (Buna-N) inline
N3 Schroeder Industries 20 3 10 µm at β(c) ≥ 200 (99.5% efficiency) 10.3 housing Nitrile (Buna-N) inline
NAS10 Schroeder Industries 20 10 10 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
NAS3 Schroeder Industries 20 3 4.8 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
NAS5 Schroeder Industries 20 5 6.3 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
NM10 Schroeder Industries 20 10 β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
NM10V Schroeder Industries 20 10 β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Fluorocarbon (Viton) inline
NM60 Schroeder Industries 20 60 β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
NM60V Schroeder Industries 20 60 β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Fluorocarbon (Viton) inline
NZ1 Schroeder Industries 20 1 4.2 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
NZ10 Schroeder Industries 20 10 10 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
NZ10V Schroeder Industries 20 10 10 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Fluorocarbon (Viton) inline
NZ1V Schroeder Industries 20 1 4.2 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Fluorocarbon (Viton) inline
NZ25 Schroeder Industries 20 25 24 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
NZ25V Schroeder Industries 20 25 24 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Fluorocarbon (Viton) inline
NZ3 Schroeder Industries 20 3 4.8 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
NZ3H.5 Schroeder Industries 20 3 4.8 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Ethylene Propylene Rubber (EPR) inline
NZ3V Schroeder Industries 20 3 4.8 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Fluorocarbon (Viton) inline
NZ5 Schroeder Industries 20 5 6.3 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
NZ5V Schroeder Industries 20 5 6.3 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Fluorocarbon (Viton) inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 46×134 mm filter elements interchangeable?
They share the same physical envelope — 46 mm OD and 134 mm length (1.81×5.28 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 21 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 46×134 mm in inches?
46×134 mm converts to approximately 1.81×5.28 in.

Browse all 46 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.