Envelope interchange · 1.97×4.57 in

50×116 mm filter elements

12 elements from 3 brand(s) share this envelope: 50 mm outside diameter and 116 mm overall length (1.97×4.57 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
HD509/2X MANN-FILTER 25 — — — housing — inline
V3.0512-05K1 ARGO-HYTOS 24 7 — 20 housing — inline
05.9800.25VG.10.E.P.4 Eaton / Internormen — 20 — 10 housing Nitrile (Buna-N) inline
05.9801.12.200.210.E.P.4 Eaton / Internormen — 10 — 210 housing Nitrile (Buna-N) inline
05.9800.25VG.10.E.V.4 Eaton / Internormen — 20 — 10 housing Fluorocarbon (Viton) inline
05.9800.6VG.10.E.P.4 Eaton / Internormen — 7 — 10 housing Nitrile (Buna-N) inline
05.9801.3VG.210.E.P.4 Eaton / Internormen — 5 — 210 housing Nitrile (Buna-N) inline
05.9801.12.200.210.E.V.4 Eaton / Internormen — 10 — 210 housing Fluorocarbon (Viton) inline
05.9801.25VG.210.E.P.4 Eaton / Internormen — 20 — 210 housing Nitrile (Buna-N) inline
05.9800.3VG.10.E.P.4 Eaton / Internormen — 5 — 10 housing Nitrile (Buna-N) inline
05.9800.12.200.10.E.P.4 Eaton / Internormen — 10 — 10 housing Nitrile (Buna-N) inline
05.9801.3VG.210.E.V.4 Eaton / Internormen — 5 — 210 housing Fluorocarbon (Viton) inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 50×116 mm filter elements interchangeable?
They share the same physical envelope — 50 mm OD and 116 mm length (1.97×4.57 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 12 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 50×116 mm in inches?
50×116 mm converts to approximately 1.97×4.57 in.

Browse all 50 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.