Envelope interchange · 2.17×2.72 in
55×69 mm filter elements
3 elements from 2 brand(s) share this envelope: 55 mm outside diameter and 69 mm overall length (2.17×2.72 in).
Dimensional interchange — verify before substituting. These cartridges fit the
same bowl space; they are not guaranteed drop-in equivalents. Compare grade,
end caps, seals, collapse rating and bypass configuration for the specific duty.
| Model | Brand | ID (mm) | Micron | β rating | Collapse (bar) | Bypass | Seal | Type |
|---|---|---|---|---|---|---|---|---|
| HD66 | MANN-FILTER | 28 | — | — | — | housing | — | inline |
| HF35237 | Fleetguard | 28.5 | 10 | 10 µm at β75(c); 11 µm at β200(c) per ISO 16889 | 15 | housing | — | inline |
| HF7919 | Fleetguard | 28.5 | 20.9 | 20.9 µm at β75(c) per ISO 16889 | 25 | housing | — | inline |
Substitution verification checklist
- Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
- End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
- Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
- Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
- Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.
Frequently asked questions
Are all 55×69 mm filter elements interchangeable?
They share the same physical envelope — 55 mm OD and 69 mm length (2.17×2.72 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 3 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 55×69 mm in inches?
55×69 mm converts to approximately 2.17×2.72 in.