Envelope interchange · 2.72×4.61 in

69×117 mm filter elements

15 elements from 1 brand(s) share this envelope: 69 mm outside diameter and 117 mm overall length (2.72×4.61 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
0160 D 003 ON HYDAC 34 3 β3 > 1000 (HYDAC grade convention: β5(c) ≥ 1000) 20 housing Nitrile (Buna-N) pressure
0160 D 003 ON /-V HYDAC 34 3 ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000) 20 housing Fluorocarbon (Viton) pressure
0160 D 005 BNK HYDAC 34 5 β5 > 1000 (HYDAC grade convention: β7(c) ≥ 1000) 20 housing Nitrile (Buna-N) pressure
0160 D 005 ON HYDAC 34 5 β5 > 1000 (HYDAC grade convention: β7(c) ≥ 1000) 20 housing Nitrile (Buna-N) pressure
0160 D 005 ON /-V HYDAC 34 5 ßx(c) ≥ 1000 (HYDAC grade convention: β7(c) ≥ 1000) 20 housing Fluorocarbon (Viton) pressure
0160 D 010 BN4HC /-SFREE HYDAC 34 10 β10 > 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 housing Nitrile (Buna-N) pressure
0160 D 020 BH4HC HYDAC 34 20 β20 > 1000 (HYDAC grade convention: β22(c) ≥ 1000) 210 housing Nitrile (Buna-N) pressure
0160 D 020 ON HYDAC 34 20 β20 > 1000 (HYDAC grade convention: β22(c) ≥ 1000) 20 housing Nitrile (Buna-N) pressure
0160 D 025 W/HC HYDAC 34 — — 20 housing Nitrile (Buna-N) pressure
0160 D 040 AM HYDAC 34 — β40 > 30 10 housing Nitrile (Buna-N) pressure
0160 D 050 W/HC HYDAC 34 — — 20 housing Nitrile (Buna-N) pressure
0160 D 074 W/HC HYDAC 34 — — 20 housing Nitrile (Buna-N) pressure
0160 D 100 W/HC HYDAC 34 — — 20 housing Nitrile (Buna-N) pressure
0160 D 149 W/HC HYDAC 34 — — 20 housing Nitrile (Buna-N) pressure
0160 D 200 W/HC HYDAC 34 — — 20 housing Nitrile (Buna-N) pressure

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 69×117 mm filter elements interchangeable?
They share the same physical envelope — 69 mm OD and 117 mm length (2.72×4.61 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 15 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 69×117 mm in inches?
69×117 mm converts to approximately 2.72×4.61 in.

Browse all 69 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.