Envelope interchange · 2.76×12.44 in

70×316 mm filter elements

9 elements from 1 brand(s) share this envelope: 70 mm outside diameter and 316 mm overall length (2.76×12.44 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
01.TS 310.10P.-.B.-.- Eaton / Internormen — 10 — — housing — suction
01.TS 310.10VG.-.B.-.- Eaton / Internormen — 10 — — housing — suction
01.TS 310.6VG.-.B.-.- Eaton / Internormen — 7 — — housing — suction
01.TS 310.16VG.-.B.-.- Eaton / Internormen — 15 — — housing — suction
01.TS 310.25VG.-.B.-.- Eaton / Internormen — 20 — — housing — suction
01.TS 310.25G.-.B.-.- Eaton / Internormen — 25 — — housing — suction
01.TS 310.40G.-.B.-.- Eaton / Internormen — 40 — 30 housing Fluorocarbon (Viton) suction
01.TS 310.80G.-.B.-.- Eaton / Internormen — 80 — — housing — suction
01.TS 310.130G.-.B.-.- Eaton / Internormen — 130 — 10 housing — suction

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 70×316 mm filter elements interchangeable?
They share the same physical envelope — 70 mm OD and 316 mm length (2.76×12.44 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 9 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 70×316 mm in inches?
70×316 mm converts to approximately 2.76×12.44 in.

Browse all 70 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.