Envelope interchange · 2.95×6.57 in
75×167 mm filter elements
40 elements from 1 brand(s) share this envelope: 75 mm outside diameter and 167 mm overall length (2.95×6.57 in).
Dimensional interchange — verify before substituting. These cartridges fit the
same bowl space; they are not guaranteed drop-in equivalents. Compare grade,
end caps, seals, collapse rating and bypass configuration for the specific duty.
| Model | Brand | ID (mm) | Micron | β rating | Collapse (bar) | Bypass | Seal | Type |
|---|---|---|---|---|---|---|---|---|
| 01.E 175.10P.16.E.P.- | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.10P.16.S.P.- | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.10VG.16.E.P.- | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.10VG.16.S.P.- | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.25VG.16.E.P.- | Eaton / Internormen | — | 20 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.25VG.16.S.P.- | Eaton / Internormen | — | 20 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.25G.16.E.P.- | Eaton / Internormen | — | 25 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.25G.16.E.P.VA | Eaton / Internormen | — | 25 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.25G.16.S.P.- | Eaton / Internormen | — | 25 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.40G.16.E.P.- | Eaton / Internormen | — | 40 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.40G.16.E.P.VA | Eaton / Internormen | — | 40 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.40G.16.S.P.- | Eaton / Internormen | — | 40 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.80G.16.E.P.- | Eaton / Internormen | — | 80 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.80G.16.S.P.- | Eaton / Internormen | — | 80 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.16VG.16.E.P.- | Eaton / Internormen | — | 15 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.3VG.16.E.P.- | Eaton / Internormen | — | 5 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.10VG.16.E.P.VA | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.10G.16.E.P.- | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.80G.16.E.P.VA | Eaton / Internormen | — | 80 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.6VG.16.E.P.- | Eaton / Internormen | — | 7 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.130G.16.E.P.- | Eaton / Internormen | — | 130 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.60G.16.E.P.- | Eaton / Internormen | — | 60 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.60G.16.S.P.- | Eaton / Internormen | — | 60 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.130G.16.S.P.- | Eaton / Internormen | — | 130 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.100G.16.E.P.- | Eaton / Internormen | — | 100 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.250G.16.E.P.- | Eaton / Internormen | — | 250 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.40G.16.E.V.- | Eaton / Internormen | — | 40 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 175.25G.16.E.V.- | Eaton / Internormen | — | 25 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 175.10VG.16.E.V.- | Eaton / Internormen | — | 10 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 175.3VG.16.S.P.- | Eaton / Internormen | — | 5 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.80G.16.S.V.- | Eaton / Internormen | — | 80 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 175.10VG.16.S.V.- | Eaton / Internormen | — | 10 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 175.25VG.16.E.V.- | Eaton / Internormen | — | 20 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 175.10G.16.E.V.- | Eaton / Internormen | — | 10 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 175.25VG.16.S1.P.- | Eaton / Internormen | — | 20 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.3VG.16.S1.P.- | Eaton / Internormen | — | 5 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 175.16VG.16.E.V.- | Eaton / Internormen | — | 15 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 175.25G.16.E.V.VA | Eaton / Internormen | — | 25 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 175.3VG.16.E.V.- | Eaton / Internormen | — | 5 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 175.40G.16.S1.P.- | Eaton / Internormen | — | 40 | — | 16 | housing | Nitrile (Buna-N) | return |
Substitution verification checklist
- Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
- End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
- Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
- Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
- Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.
Frequently asked questions
Are all 75×167 mm filter elements interchangeable?
They share the same physical envelope — 75 mm OD and 167 mm length (2.95×6.57 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 40 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 75×167 mm in inches?
75×167 mm converts to approximately 2.95×6.57 in.
Browse all 75 mm OD elements or open the dimensions finder.
Request quote & availability
First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.