ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
2.450 D 03 BN4 HYDAC 48 3 β3 > 1000 (HYDAC grade convention: β5(c) ≥ 1000) 20 housing Nitrile (Buna-N) pressure
2.450 D 06 BN4 HYDAC 48 6 β6 > 1000 20 housing Nitrile (Buna-N) pressure
2.450 D 10 BH4 HYDAC 48 10 β10 > 1000 (HYDAC grade convention: β12(c) ≥ 1000) 210 housing Nitrile (Buna-N) pressure
2.450 D 10 BN4 HYDAC 48 10 β10 > 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 housing Nitrile (Buna-N) pressure
2.450 D 25 BN4 HYDAC 48 25 β25 > 1000 20 housing Nitrile (Buna-N) pressure
2.450 D 50 W HYDAC 48 50 — 20 housing Nitrile (Buna-N) pressure

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 84×373 mm filter elements interchangeable?
They share the same physical envelope — 84 mm OD and 373 mm length (3.31×14.69 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 6 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 84×373 mm in inches?
84×373 mm converts to approximately 3.31×14.69 in.

Browse all 84 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.