Envelope interchange · 3.90×18.39 in

99×467 mm filter elements

24 elements from 1 brand(s) share this envelope: 99 mm outside diameter and 467 mm overall length (3.90×18.39 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
18LC10 Schroeder Industries 58 10 18 µm at β(c) ≥ 200 (99.5% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LC25 Schroeder Industries 58 25 β(c) ≥ 1000 (99.5% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LC3 Schroeder Industries 58 3 10 µm at β(c) ≥ 200 (99.5% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LCI10 Schroeder Industries 58 10 18 µm at β(c) ≥ 200 (99.5% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LCI25 Schroeder Industries 58 25 β(c) ≥ 1000 (99.5% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LCI3 Schroeder Industries 58 3 10 µm at β(c) ≥ 200 (99.5% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LCIZ1 Schroeder Industries 58 1 4.2 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LCIZ10 Schroeder Industries 58 10 10 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LCIZ25 Schroeder Industries 58 25 24 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LCIZ3 Schroeder Industries 58 3 4.8 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LCIZ5 Schroeder Industries 58 5 6.3 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LCZ1 Schroeder Industries 58 1 4.2 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LCZ10 Schroeder Industries 58 10 10 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LCZ10H.5 Schroeder Industries 58 10 10 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Ethylene Propylene Rubber (EPR) inline
18LCZ10V Schroeder Industries 58 10 10 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Fluorocarbon (Viton) inline
18LCZ1V Schroeder Industries 58 1 4.2 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Fluorocarbon (Viton) inline
18LCZ25 Schroeder Industries 58 25 24 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LCZ25H Schroeder Industries 58 25 24 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Ethylene Propylene Rubber (EPR) inline
18LCZ25V Schroeder Industries 58 25 24 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Fluorocarbon (Viton) inline
18LCZ3 Schroeder Industries 58 3 4.8 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LCZ3H.5 Schroeder Industries 58 3 4.8 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Ethylene Propylene Rubber (EPR) inline
18LCZ3V Schroeder Industries 58 3 4.8 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Fluorocarbon (Viton) inline
18LCZ5 Schroeder Industries 58 5 6.3 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Nitrile (Buna-N) inline
18LCZ5V Schroeder Industries 58 5 6.3 µm at β(c) ≥ 1000 (99.9% efficiency) 10.3 housing Fluorocarbon (Viton) inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 99×467 mm filter elements interchangeable?
They share the same physical envelope — 99 mm OD and 467 mm length (3.90×18.39 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 24 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 99×467 mm in inches?
99×467 mm converts to approximately 3.90×18.39 in.

Browse all 99 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.