ARGO-HYTOS · Filter Elements · inline line

V3.0421-55K1 filter element: specifications & equivalents

The V3.0421-55K1 is a ARGO-HYTOS inline-line hydraulic filter element, built with glass fiber media, sized 40 × 212 mm OD × length (ID 14.5 mm), rated at 6 µm class. Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 40 × 212 mm
Inside diameter 14.5 mm
Filtration rating 6 µm nom.
Media Glass fiber
Collapse / burst 20 bar
Line type inline
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.90.

Dimensions, filter fineness and collapse pressure are taken from the ARGO-HYTOS product portal. Beta efficiency per ISO 16889 and seal material vary by execution — verify against the current ARGO-HYTOS data sheet before ordering.

Specification table

ParameterValue
Filter type inline line
Media Glass fiber
Filtration rating 6 µm
Rating basis nominal
Outside diameter OD 40 mm
Inside diameter ID 14.5 mm
Length 212 mm
End caps open-ended cartridge element
Collapse / burst pressure 20 bar
Integral bypass valve none (housing/valve-dependent)
Mass 171 g
Manufacturer part no. 40249400
Source catalog ARGO-HYTOS: ARGO-HYTOS product portal (portal.argo-hytos.com)
Last verified2026-09-28

Sources: ARGO-HYTOS — ARGO-HYTOS product portal (portal.argo-hytos.com) — accessed 2026-09-28.

ARGO-HYTOS® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized ARGO-HYTOS distributor.

Dimensions & series range

Outside diameter40 mm (1.575 in)
Inside diameter14.5 mm (0.571 in)
Overall length212 mm (8.346 in)

Cross references & equivalents

No catalog-verified cross references yet. This model is in the manual verification queue — request a verified equivalent.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the V3.0421-55K1 model number is decoded

  • V3.0421-55K1ARGO-HYTOS filter element part number (EXAPOR® MAX Element) per the official product portal.
  • 6 µmPublished filter fineness (nominal rating as printed by ARGO-HYTOS).
  • 40 mmOuter diameter.
  • 14.5 mmInner diameter.
  • 212 mmElement length.
  • 20 barElement collapse pressure rating.
  • 7 barBypass valve opening pressure.
  • Glass fiberFilter media.

Typical equipment & applications

  • Replacement element for ARGO-HYTOS hydraulic filter housings
  • Mobile and industrial hydraulic circuits

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the V3.0421-55K1 filter element?
The published envelope is 40 mm OD × 212 mm length with a 14.5 mm inside diameter (1.575 × 8.346 in × 0.571 in ID). Confirm against the housing drawing before ordering.
What micron rating does V3.0421-55K1 use?
This element is rated 6 µm (nominal class). Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the V3.0421-55K1 filter element?
Cross references are being verified for this model — use the inquiry form and the engineering desk will confirm equivalents.
How do I read the V3.0421-55K1 part number?
See the designation decoder above: each segment of AHV3042155K1 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the Filter Elements series

All 662 →

Reviewed & verified by the ElementRef engineering desk against ARGO-HYTOS on 2026-09-28. Read our editorial & correction policy.