Baldwin Filters · Form 561 Interchange · inline line

H9092 filter element: specifications & equivalents

The H9092 is a Baldwin Filters inline-line hydraulic filter element. Verify against the current manufacturer data sheet before ordering.

Line type inline
Partially verified. Fit and grade trace to an official interchange document; dimensional values are compiled from 0 aftermarket listing(s) and must be confirmed against the manufacturer housing drawing. Confidence score 0.80.

Form 561 is a cross-reference only — Baldwin prints no dimensions, micron rating, collapse pressure or seal data for this part number here. Verify every specification against the current Baldwin data sheet before ordering.

Specification table

ParameterValue
Filter type inline line
Integral bypass valve none (housing/valve-dependent)
Manufacturer part no. H9092
Source catalog Baldwin Filters: Baldwin Filters Form 561
Last verified2026-09-30

Sources: Baldwin Filters — Baldwin Filters Form 561 — accessed 2026-09-30.

Baldwin Filters® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Baldwin Filters distributor.

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ 11108D17BH
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 11108D17BH (HYDAC) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 4ZUF8
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 4ZUF8 (GRAINGER) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 57863WIX FilterspartialBaldwin's Form 561 Number-Finder cross-reference lists 57863 (WIX) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 7863
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 7863 (NA) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 9314810
page in verification queue
UFIpartialBaldwin's Form 561 Number-Finder cross-reference lists 9314810 (PUROLATOR) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ A84863
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists A84863 (CARQUEST) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ ASHF7483
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists ASHF7483 (FL) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ E6021B2U25
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists E6021B2U25 (WESTERN TOOL CO.) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ EL9600EAH204N2
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists EL9600EAH204N2 (PUROLATOR-FACET) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ FIHY20705
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists FI HY20705 (SFF) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ GHF30480
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists GHF30480 (FL) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ GHF7083
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists GHF7083 (FLEETGUARD) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ GHP61L815MB
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists GHP61L815MB (HYP) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HC9601FDT8HPallpartialBaldwin's Form 561 Number-Finder cross-reference lists HC9601FDT8H (PALL) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HF30480FleetguardpartialFleetguard's online catalog lists H9092 as an interchange for HF30480. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HH960118010BHV
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists HH960118010BHV (HY) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ IT303350
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists IT303350 (INT) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ IXW0810HN
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists IXW0810HN (ZINGA) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ KPR3464
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists KPR3464 (PARKER) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ LHC9601FKT8H
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists LHC9601FKT8H (PALL) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ LHC9601FUT8H
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists LHC9601FUT8H (PALL) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ LHC9601FUT8Z
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists LHC9601FUT8Z (PALL) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ LND141G25B
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists LND141G25B (FILTREC) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ LRHFR87483
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists LRHFR87483 (FLEETRITE) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ MCH802FV21
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists MCH802FV21 (SOFIMA) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ MP9314809
page in verification queue
MP FiltripartialBaldwin's Form 561 Number-Finder cross-reference lists MP9314809 (PUROLATOR) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ OWGPT96108
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists O WGPT96108 (WOO) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ P03108110S63
page in verification queue
DonaldsonpartialBaldwin's Form 561 Number-Finder cross-reference lists P03108110S63 (FLUITEK) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ PASP070F10V
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists PASP070F10V (STAUFF) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ PASP070F20B
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists PASP070F20B (STAUFF) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ R5960125VG210EP8
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists R5960125VG210EP8 (INTERNORMEN) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ R961H0815A
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists R961H0815A (FAIREY-ARLON) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ R961Z0815A
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists R961Z0815A (FAIREY-ARLON) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ R961Z0825A
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists R961Z0825A (FAIREY-ARLON) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RHFR87083
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RHFR87083 (FL) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RK927175
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RK927175 (PARR FILTERS) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RK927178
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RK927178 (PARR FILTERS) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RSBF96018S15B
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RSBF96018S15B (SCH) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RSBF96018Z25B
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RSBF96018Z25B (SCH) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ SY8960H15B08
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists SY8960H15B08 (SET) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ UFLH4245
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists UFLH4245 (LUBER-FINER) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ USF9601815UM
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists USF9601815UM (SWI) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ X960820HC
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists X960820HC (NAT) as replaced by Baldwin H9092. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the H9092 model number is decoded

  • H9092Baldwin filter part number per the Form 561 Number-Finder cross-reference.

Typical equipment & applications

  • Hydraulic / transmission filtration — listed in the Baldwin Form 561 Number-Finder cross-reference.

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What replaces the H9092 filter element?
43 partial match(es) requiring parameter review
How do I read the H9092 part number?
See the designation decoder above: each segment of H9092 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the Form 561 Interchange series

All 1208 →

Reviewed & verified by the ElementRef engineering desk against Baldwin Filters on 2026-09-30. Read our editorial & correction policy.