Eaton / Internormen · 01.E / 01.N / Easy-Fit · pressure line

01.E 450.6VG.HR.E.P.- filter element: specifications & equivalents

The 01.E 450.6VG.HR.E.P.- is a Eaton / Internormen pressure-line hydraulic filter element, built with glass fiber fleece (vg) media, sized 60 × 415 mm OD × length, rated at 7 µm absolute. Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 60 × 415 mm
Filtration rating 7 µm abs.
Media Glass fiber fleece (VG)
Collapse / burst 160 bar
Line type pressure
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.90.

Specs come from Eaton's product data hub via its site-search API. The µm retention rating follows ISO 16889 (absolute convention), while the model-code fineness grade is nominal — match both before substituting.

Specification table

ParameterValue
Filter type pressure line
Media Glass fiber fleece (VG)
Filtration rating 7 µm
Rating basis absolute
Outside diameter OD 60 mm
Length 415 mm
End caps open-ended cartridge element
Collapse / burst pressure 160 bar
Integral bypass valve none (housing/valve-dependent)
Seal material Nitrile (Buna-N)
Manufacturer part no. 300263
Source catalog Eaton: Eaton product data hub via site search API (eaton.com)
Last verified2026-09-28

Sources: Eaton — Eaton product data hub via site search API (eaton.com) — accessed 2026-09-29.

Eaton / Internormen® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Eaton / Internormen distributor.

Dimensions & series range

Outside diameter60 mm (2.362 in)
Overall length415 mm (16.339 in)

All 60×415 mm interchange elements →

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ 938215Q
page in verification queue
AftermarketpartialEaton's filtration cross-reference lists 938215Q (Parker) as an interchange for 01.E 450.6VG.HR.E.P.-. Envelope cross-reference; verify micron grade, delta-P rating and seal configuration before substituting.
↔ SN-120-F-05-BSTAUFFpartialSTAUFF Filter Interchange lists 01.E450. 6VG.HR.E.P (INTERNORMEN) as replaced by SN-120-F-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the 01.E 450.6VG.HR.E.P.- model number is decoded

  • 01.E 450.6VG.HR.E.P.-Eaton 01.E Pressure filter element model code (Eaton 01.E Pressure Filter Element).
  • 300263Eaton catalog number (order code) for the same element.
  • 6 VGFilter fineness grade: nominal rating and media letter.
  • 7 µmISO 16889 multipass retention rating as published by Eaton.
  • Glass fiber fleece (VG)Filter media execution.
  • 160 barDelta-P resistance class — maximum differential pressure (collapse) rating.
  • Nitrile (Buna-N)Seal compound.
  • 60 mmOuter diameter.
  • 415 mmElement height.

Typical equipment & applications

  • Pressure-line hydraulic filters upstream of control valves
  • High-differential-pressure industrial hydraulic circuits
  • Hydraulic power units for steel, paper and power generation

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the 01.E 450.6VG.HR.E.P.- filter element?
The published envelope is 60 mm OD × 415 mm length (2.362 × 16.339 in). Confirm against the housing drawing before ordering.
What micron rating does 01.E 450.6VG.HR.E.P.- use?
This element is rated 7 µm absolute. Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the 01.E 450.6VG.HR.E.P.- filter element?
2 partial match(es) requiring parameter review
How do I read the 01.E 450.6VG.HR.E.P.- part number?
See the designation decoder above: each segment of 01E4506VGHREP encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Same-envelope elements from other brands

View full interchange →

These 69 catalog element(s) share the 60×415 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.

Other models in the 01.E / 01.N / Easy-Fit series

All 3329 →