Eaton / Internormen · 01.E / 01.N / Easy-Fit · inline line

404211 filter element: specifications & equivalents

The 404211 is a Eaton / Internormen inline-line hydraulic filter element. Verify against the current manufacturer data sheet before ordering.

Line type inline
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.90.

Specs come from Eaton's product data hub via its site-search API. The µm retention rating follows ISO 16889 (absolute convention), while the model-code fineness grade is nominal — match both before substituting.

Specification table

ParameterValue
Filter type inline line
End caps open-ended cartridge element
Integral bypass valve none (housing/valve-dependent)
Manufacturer part no. 404211
Source catalog Eaton: Eaton product data hub via site search API (eaton.com)
Last verified2026-09-28

Sources: Eaton — Eaton product data hub via site search API (eaton.com) — accessed 2026-09-29.

Eaton / Internormen® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Eaton / Internormen distributor.

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ HF6219FleetguardpartialFleetguard's online catalog lists 404211 as an interchange for HF6219. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the 404211 model number is decoded

  • 404211Eaton 10M LONG Vickers filter element model code (Eaton 10M LONG Vickers In-Line Filter Element).
  • 404211Eaton catalog number (order code) for the same element.

Typical equipment & applications

  • Medium-pressure in-line and lubrication circuits
  • Spin-on and exchange element replacements

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What replaces the 404211 filter element?
1 partial match(es) requiring parameter review
How do I read the 404211 part number?
See the designation decoder above: each segment of 404211 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the 01.E / 01.N / Easy-Fit series

All 3329 →