Fleetguard · HF Hydraulic · inline line

HF7907 filter element: specifications & equivalents

The HF7907 is a Fleetguard inline-line hydraulic filter element, sized 140 × 255.5 mm OD × length (ID 65.5 mm), rated at 57 µm absolute (57 µm at β75(c) per ISO 16889). Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 140 × 255.5 mm
Inside diameter 65.5 mm
Filtration rating 57 µm abs.
Beta rating 57 µm at β75(c) per ISO 16889
Collapse / burst 5 bar
Line type inline
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.90.

Specifications and cross-references are taken from the Fleetguard online catalog API. Where both TWA and Beta ratings are published the conventions differ — verify cleanliness targets, collapse rating and seal configuration against the current Fleetguard data sheet before ordering.

Specification table

ParameterValue
Filter type inline line
Filtration rating 57 µm
Rating basis absolute
Beta ratio 57 µm at β75(c) per ISO 16889
Outside diameter OD 140 mm
Inside diameter ID 65.5 mm
Length 255.5 mm
End caps open-ended cartridge element
Rated flow 60 L/min
Collapse / burst pressure 5 bar
Integral bypass valve none (housing/valve-dependent)
Manufacturer part no. HF7907
Source catalog Cummins Filtration / Fleetguard: Fleetguard online product catalog (fleetguard.com)
Last verified2026-09-28

Sources: Cummins Filtration / Fleetguard — Fleetguard online product catalog (fleetguard.com) — accessed 2026-09-28.

Fleetguard® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Fleetguard distributor.

Dimensions & series range

Outside diameter140 mm (5.512 in)
Inside diameter65.5 mm (2.579 in)
Overall length255.5 mm (10.059 in)

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ 52805
page in verification queue
AftermarketpartialFleetguard's online catalog lists 52805 as an interchange for HF7907. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ CL2206
page in verification queue
AftermarketpartialFleetguard's online catalog lists CL2206 as an interchange for HF7907. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ CR2203
page in verification queue
AftermarketpartialFleetguard's online catalog lists CR2203 as an interchange for HF7907. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HF0790700
page in verification queue
FleetguardpartialFleetguard's online catalog lists HF0790700 as an interchange for HF7907. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HF0790700MX
page in verification queue
FleetguardpartialFleetguard's online catalog lists HF0790700MX as an interchange for HF7907. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ PT23469Baldwin FilterspartialBaldwin's Form 561 Number-Finder cross-reference lists HF7907 (FLEETGUARD) as replaced by Baldwin PT23469. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ TE115CV1
page in verification queue
AftermarketpartialFleetguard's online catalog lists TE115CV1 as an interchange for HF7907. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the HF7907 model number is decoded

  • HF7907Fleetguard HF-series hydraulic cartridge element part number.
  • 255.5 mmOverall height.
  • 140 mmLargest outside diameter.
  • 65.5 mmLargest end inside diameter.
  • 57 µm at β75(c) per ISO 16889Published efficiency ratings.

Typical equipment & applications

  • Construction, agricultural and industrial hydraulic circuits
  • Mobile-equipment hydraulic return and pressure lines

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the HF7907 filter element?
The published envelope is 140 mm OD × 255.5 mm length with a 65.5 mm inside diameter (5.512 × 10.059 in × 2.579 in ID). Confirm against the housing drawing before ordering.
What micron rating does HF7907 use?
This element is rated 57 µm absolute — 57 µm at β75(c) per ISO 16889. Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the HF7907 filter element?
7 partial match(es) requiring parameter review
How do I read the HF7907 part number?
See the designation decoder above: each segment of HF7907 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the HF Hydraulic series

All 2621 →

Reviewed & verified by the ElementRef engineering desk against Cummins Filtration / Fleetguard on 2026-09-28. Read our editorial & correction policy.