HYDAC · Betamicron 4 R · return line
0500 R 003 ON /-KB filter element: specifications & equivalents
The 0500 R 003 ON /-KB is a HYDAC return-line hydraulic filter element, built with on=optimicron low-press. media, sized 94 × 276.9 mm OD × length (ID 48 mm), rated at 3 µm absolute (ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000)). Verify against the current manufacturer data sheet before ordering.
Dimensions, ratings and seal compound are taken directly from the HYDAC electronic catalog (catalog.hydac.com). Outside diameter and length are converted from the inch values printed on the catalog page; verify against the current HYDAC data sheet before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | return line |
| Media | ON=Optimicron low-press. |
| Filtration rating | 3 µm |
| Rating basis | absolute |
| Beta ratio | ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000) |
| Outside diameter OD | 94 mm |
| Inside diameter ID | 48 mm |
| Length | 276.9 mm |
| End caps | open-ended cartridge element |
| Flow direction | outside-in |
| Collapse / burst pressure | 20 bar |
| Integral bypass valve | none (housing/valve-dependent) |
| Seal material | Nitrile (Buna-N) |
| Operating temperature | -30 to 100 °C |
| Source catalog | HYDAC Technology Corporation: HYDAC electronic product catalog (catalog.hydac.com) |
| Last verified | 2026-09-28 |
Sources: HYDAC Technology Corporation — HYDAC electronic product catalog (catalog.hydac.com) — accessed 2026-09-29.
HYDAC® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized HYDAC distributor.
Dimensions & series range
| Outside diameter | 94 mm (3.701 in) |
| Inside diameter | 48 mm (1.890 in) |
| Overall length | 276.9 mm (10.902 in) |
All 94×277 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
| ↔ RE-130-G-03-B-NB | STAUFF | partial | STAUFF Filter Interchange lists 0500 R 003 ON /-KB (HYDAC) as replaced by RE-130-G-03-B-NB. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the 0500 R 003 ON /-KB model number is decoded
- 0500 R 003 ON /-KBHYDAC Type R filter element ordering code per the HYDAC electronic catalog (s16).
- ON=Optimicron low-press.Filter media and collapse family as printed in the catalog.
- 3 µmAbsolute filter rating per the HYDAC catalog.
- ßx(c) ≥ 1000Beta ratio rating as printed in the catalog.
- 94 mmOutside diameter.
- 48 mmInner diameter.
- 276.9 mmElement length.
- 20 barElement collapse (differential pressure) rating.
- Nitrile (Buna-N)Seal compound.
Typical equipment & applications
- Return-line filtration for HYDAC RF/RFM and equivalent housings
- Industrial and mobile hydraulic systems
Selection pitfalls — read before you substitute
- A return-line element is not a pressure-line element: return cartridges (BN4HC low-collapse) tolerate roughly 20 bar differential, while BH4HC pressure executions are rated to 210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
- This element has no integral bypass — opening pressure is set by the housing’s reusable bypass valve. Confirm the valve setting (commonly 3.4 bar) is present before fitting.
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- Fine 3 µm media loads faster and runs at a higher cold Δp than coarser grades — only downgrade cleanliness targets if the system ISO 4406 code allows it.
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What are the dimensions of the 0500 R 003 ON /-KB filter element?
What micron rating does 0500 R 003 ON /-KB use?
What replaces the 0500 R 003 ON /-KB filter element?
How do I read the 0500 R 003 ON /-KB part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Same-envelope elements from other brands
View full interchange →These 43 catalog element(s) share the 94×277 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Betamicron 4 R series
All 929 →Reviewed & verified by the ElementRef engineering desk against HYDAC Technology Corporation on 2026-09-28. Read our editorial & correction policy.