Pall · Supralon · inline line

HC8314FRN39HX472 filter element: specifications & equivalents

The HC8314FRN39HX472 is a Pall inline-line hydraulic filter element, built with glassfiber media, rated at 7 µm absolute (βx(c)≥2000). Verify against the current manufacturer data sheet before ordering.

Filtration rating 7 µm abs.
Beta rating β x(c)≥2000
Media glassfiber
Line type inline
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-10-01. Confidence score 0.90.

Pall's Lube & Hydraulic Crossover Tool prints removal rating, nominal length and seal only for elements — no OD, ID, collapse or bypass data. Verify envelope dimensions against the current Pall data sheet before ordering. Anti-static construction per the crossover tool.

Specification table

ParameterValue
Filter type inline line
Media glassfiber
Filtration rating 7 µm
Rating basis absolute
Beta ratio βx(c)≥2000
Length 990.6 mm
Nominal length code 39 in
Integral bypass valve none (housing/valve-dependent)
Seal material Nitrile (Buna-N)
Manufacturer part no. HC8314FRN39HX472
Source catalog Pall Corporation (Danaher): Pall Lube & Hydraulic Crossover Tool
Last verified2026-10-01

Sources: Pall Corporation (Danaher) — Pall Lube & Hydraulic Crossover Tool — accessed 2026-10-01.

Pall® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Pall distributor.

Dimensions & series range

Overall length990.6 mm (39.000 in)
Nominal length code39 inches

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ HC8314FKN39HX472PallfullPall Lube & Hydraulic Crossover Tool (manufacturer direct replacement).

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the HC8314FRN39HX472 model number is decoded

  • HC8314FRN39HX472Pall Supralon part number per the Pall Lube & Hydraulic Crossover Tool, with current Supralon replacement mapping.

Typical equipment & applications

  • Supralon hydraulic/lube-oil filter element per Pall’s official crossover mapping.

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What micron rating does HC8314FRN39HX472 use?
This element is rated 7 µm absolute — βx(c)≥2000. Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the HC8314FRN39HX472 filter element?
1 catalog-confirmed full match(es) (HC8314FKN39HX472)
How do I read the HC8314FRN39HX472 part number?
See the designation decoder above: each segment of HC8314FRN39HX472 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the Supralon series

All 1523 →