STAUFF · Replacement Elements · inline line

NL-040-F-03-B filter element: specifications & equivalents

The NL-040-F-03-B is a STAUFF inline-line hydraulic filter element, sized 44.5 × 99 mm OD × length (ID 22.2 mm). Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 44.5 × 99 mm
Inside diameter 22.2 mm
Line type inline
Partially verified. Fit and grade trace to an official interchange document; dimensional values are compiled from 0 aftermarket listing(s) and must be confirmed against the manufacturer housing drawing. Confidence score 0.85.

Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.

Specification table

ParameterValue
Filter type inline line
Outside diameter OD 44.5 mm
Inside diameter ID 22.2 mm
Length 99 mm
Integral bypass valve none (housing/valve-dependent)
Source catalog STAUFF: STAUFF Filter Interchange online database (filterinterchange.com)
Last verified2026-09-28

Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.

STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.

Dimensions & series range

Outside diameter44.5 mm (1.752 in)
Inside diameter22.2 mm (0.874 in)
Overall length99 mm (3.898 in)

All 45×99 mm interchange elements →

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ 0040 DN 003 BH4HCHYDACpartialSTAUFF Filter Interchange lists 0040 DN 003 BH4HC (HYDAC) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 0040DN003BHHC
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 0040 DN 003 BH/HC (HYDAC) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 01.NL 40.3VG.HR.E.P.-Eaton / InternormenpartialSTAUFF Filter Interchange lists 01NL403VGHREP (INTERNORMEN) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 1265318
page in verification queue
UFIpartialSTAUFF Filter Interchange lists 1265318 (HYDAC) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 20040H3SLB
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 20040H3SLB (EPE / Bosch-Rexroth Filtration) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 20040H3SLB000P
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 20040H3SLB000P (EPE / Bosch-Rexroth Filtration) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 20040H3XLB000M
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 2.0040H3XL-B00-0-M (EPE / Bosch-Rexroth Filtration) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 20040PWR3B
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 20040PWR3B (EPE / Bosch-Rexroth Filtration) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 20040PWR3B000M
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 2.0040PWR3-B00-0-M (EPE / Bosch-Rexroth Filtration) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 20040PWR3B000P
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 20040PWR3B000P (EPE / Bosch-Rexroth Filtration) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ FDAE1A02QH
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists FDAE 1A02QH (PARKER) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ N0040DH2003
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists N0040DH2003 (COMEX / Ecoparts) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ N0040DH3
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists N0040DH3 (COMEX / Ecoparts) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ PI71004DN
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists PI 71004DN (MAHLE / Filtration Group) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ XD040G03B
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists XD040G03B (FILTREC) as replaced by NL-040-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the NL-040-F-03-B model number is decoded

  • NL-040-F-03-BSTAUFF replacement element part number per the STAUFF Filter Interchange database.

Typical equipment & applications

  • Replacement element for OEM hydraulic filter housings

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the NL-040-F-03-B filter element?
The published envelope is 44.5 mm OD × 99 mm length with a 22.2 mm inside diameter (1.752 × 3.898 in × 0.874 in ID). Confirm against the housing drawing before ordering.
What replaces the NL-040-F-03-B filter element?
15 partial match(es) requiring parameter review
How do I read the NL-040-F-03-B part number?
See the designation decoder above: each segment of NL040F03B encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Same-envelope elements from other brands

View full interchange →

These 41 catalog element(s) share the 45×99 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.

Other models in the Replacement Elements series

All 4930 →

Reviewed & verified by the ElementRef engineering desk against STAUFF on 2026-09-28. Read our editorial & correction policy.