STAUFF · Replacement Elements · inline line
RP-200-E-03-B filter element: specifications & equivalents
The RP-200-E-03-B is a STAUFF inline-line hydraulic filter element, sized 152 × 423 mm OD × length (ID 82.3 mm). Verify against the current manufacturer data sheet before ordering.
Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | inline line |
| Outside diameter OD | 152 mm |
| Inside diameter ID | 82.3 mm |
| Length | 423 mm |
| Integral bypass valve | none (housing/valve-dependent) |
| Source catalog | STAUFF: STAUFF Filter Interchange online database (filterinterchange.com) |
| Last verified | 2026-09-28 |
Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.
STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.
Dimensions & series range
| Outside diameter | 152 mm (5.984 in) |
| Inside diameter | 82.3 mm (3.240 in) |
| Overall length | 423 mm (16.654 in) |
All 152×423 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
|
↔ 01269059 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 01269059 (HYDAC) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ 05.8400.3VG.10.B.P.16 | Eaton / Internormen | partial | STAUFF Filter Interchange lists 05.8400. 3VG.10.B.P.16 (INTERNORMEN) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 168400UH3SLS000P page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 16.8400UH3SLS000P (EPE / Bosch-Rexroth Filtration) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 168400UH3XLS000P page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 16.8400 / U H3XL-S00-0-P (EPE / Bosch-Rexroth Filtration) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 30354 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 30.354 (MODINA (SOFIMA)) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 8400163UM page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 8400163UM (TRIBOGUARD) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ BE84001603A page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists BE8400/16-03A (BEHRINGER) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ FC1362F003BS page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists FC1362F003BS (FINNFILTER) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ H840016003BN page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists H8400/16 003 BN (HYDAC) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ HF30686 | Fleetguard | partial | Fleetguard's online catalog lists RP200E03B as an interchange for HF30686. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting. |
| ↔ HF7016 | Fleetguard | partial | STAUFF Filter Interchange lists HF7016 (FLEETGUARD / CUMMINS) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HP84L163MB page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists HP84L163MB (HY-PRO) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ PT23355-MPG | Baldwin Filters | partial | Baldwin's Form 561 Number-Finder cross-reference lists RP200E03B (STAUFF) as replaced by Baldwin PT23355-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ R442G03 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists R442G03 (FILTREC) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ R928016745 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists R 928016745 (EPE / Bosch-Rexroth Filtration) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ SBF840016S1B page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists SBF-8400-16S1B (SCHROEDER) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ SBF-8400-16Z3B | Schroeder Industries | partial | STAUFF Filter Interchange lists SBF-8400-16Z3B (SCHROEDER) as replaced by RP-200-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the RP-200-E-03-B model number is decoded
- RP-200-E-03-BSTAUFF replacement element part number per the STAUFF Filter Interchange database.
Typical equipment & applications
- Replacement element for OEM hydraulic filter housings
Selection pitfalls — read before you substitute
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What are the dimensions of the RP-200-E-03-B filter element?
What replaces the RP-200-E-03-B filter element?
How do I read the RP-200-E-03-B part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Same-envelope elements from other brands
View full interchange →These 21 catalog element(s) share the 152×423 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Replacement Elements series
All 4930 →Reviewed & verified by the ElementRef engineering desk against STAUFF on 2026-09-28. Read our editorial & correction policy.