STAUFF · Replacement Elements · inline line

SP-020-E-05-B filter element: specifications & equivalents

The SP-020-E-05-B is a STAUFF inline-line hydraulic filter element, sized 45.5 × 207 mm OD × length (ID 25.6 mm). Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 45.5 × 207 mm
Inside diameter 25.6 mm
Line type inline
Partially verified. Fit and grade trace to an official interchange document; dimensional values are compiled from 0 aftermarket listing(s) and must be confirmed against the manufacturer housing drawing. Confidence score 0.85.

Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.

Specification table

ParameterValue
Filter type inline line
Outside diameter OD 45.5 mm
Inside diameter ID 25.6 mm
Length 207 mm
End caps open-ended cartridge element
Integral bypass valve none (housing/valve-dependent)
Source catalog STAUFF: STAUFF Filter Interchange online database (filterinterchange.com)
Last verified2026-09-28

Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.

STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.

Dimensions & series range

Outside diameter45.5 mm (1.791 in)
Inside diameter25.6 mm (1.008 in)
Overall length207 mm (8.150 in)

All 46×207 mm interchange elements →

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ 01262455
page in verification queue
UFIpartialSTAUFF Filter Interchange lists 01262455 (HYDAC) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 1016065
page in verification queue
UFIpartialSTAUFF Filter Interchange lists 101606-5 (PARKER) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 87832N
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 87832N (NELSON WINSLOW) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 932618QParkerpartialSTAUFF Filter Interchange lists 932618Q (PARKER) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 933246QParkerpartialSTAUFF Filter Interchange lists 933246Q (PARKER) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ CCH153FC1
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists CCH153FC1 (SOFIMA) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ CH153FC1
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists CH 153FC1 (MODINA (SOFIMA)) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ CH153FC11
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists CH153FC11 (SOFIMA) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ CHP283F06XN
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists CHP283F06XN (OMT) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ CHP283NXN
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists CHP283NXN (OMT) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ CM29001
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists CM290.01 (DONALDSON) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ DE3041B2C05
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists DE3041B2C05 (DENISON) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ FFKPVL171225ABS
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists FFKPVL171225ABS (FINNFILTER) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ HD514/1MANN-FILTERpartialMANN-FILTER's online catalog lists SP-020E05B (STAUFF) as a comparison number for HD5141. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HF30062FleetguardpartialFleetguard's online catalog lists SP020E05B as an interchange for HF30062. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HP0653A06AN
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists HP0653A06AN (MP-FILTRI) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ HP0653A06NA
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists HP0653A06NA (MP-FILTRI) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ HP20L86MB
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists HP20L8-6MB (HY-PRO) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ LHX95108
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists LHX95108 (LUBER-FINER) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ MDH7324
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists MDH7324 (MDF) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ R928016859
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists R 928016859 (EPE / Bosch-Rexroth Filtration) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ SBF-9020-8Z3BSchroeder IndustriespartialSchroeder online cross-reference (STAUFF); envelope match — verify grade and seals.
↔ SBF-9020-8Z5BSchroeder IndustriespartialSchroeder online cross-reference (STAUFF); envelope match — verify grade and seals.
↔ V3041B2C05Eaton / InternormenpartialSTAUFF Filter Interchange lists V3041B2C05 (VICKERS) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ V3042B2C05
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists V3042B2C05 (VICKERS) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ V3042B2V05
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists V 3042B2V05 (VICKERS) as replaced by SP-020-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the SP-020-E-05-B model number is decoded

  • SP-020-E-05-BSTAUFF replacement element part number per the STAUFF Filter Interchange database.

Typical equipment & applications

  • Replacement element for OEM hydraulic filter housings

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the SP-020-E-05-B filter element?
The published envelope is 45.5 mm OD × 207 mm length with a 25.6 mm inside diameter (1.791 × 8.150 in × 1.008 in ID). Confirm against the housing drawing before ordering.
What replaces the SP-020-E-05-B filter element?
26 partial match(es) requiring parameter review
How do I read the SP-020-E-05-B part number?
See the designation decoder above: each segment of SP020E05B encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Same-envelope elements from other brands

View full interchange →

These 17 catalog element(s) share the 46×207 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.

Other models in the Replacement Elements series

All 4930 →

Reviewed & verified by the ElementRef engineering desk against STAUFF on 2026-09-28. Read our editorial & correction policy.