SP-024-F-10-B filter element: specifications & equivalents
The SP-024-F-10-B is a STAUFF inline-line hydraulic filter element, sized 49.5 × 115 mm OD × length (ID 23.9 mm). Verify against the current manufacturer data sheet before ordering.
Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | inline line |
| Outside diameter OD | 49.5 mm |
| Inside diameter ID | 23.9 mm |
| Length | 115 mm |
| End caps | open-ended cartridge element |
| Integral bypass valve | none (housing/valve-dependent) |
| Source catalog | STAUFF: STAUFF Filter Interchange online database (filterinterchange.com) |
| Last verified | 2026-09-28 |
Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.
STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.
Dimensions & series range
| Outside diameter | 49.5 mm (1.949 in) |
| Inside diameter | 23.9 mm (0.941 in) |
| Overall length | 115 mm (4.528 in) |
All 50×115 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
|
↔ 11304D10BH page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 1.13.04D10BH (HYDAC) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 1262445 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 1262445 (HYDAC) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 79328774 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 79328774 (COMEX / Ecoparts) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 891024PSVST10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 891024PSVST10 (MAHLE / Filtration Group) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 891024PSVST10NBR page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 891024PSVST10NBR (MAHLE / Filtration Group) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 891024SMVST10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 891024SMVST10 (MAHLE / Filtration Group) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 891024SMXVST10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 891024SMXVST10 (MAHLE / Filtration Group) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 891024SMXVST10NBR page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 891024SMXVST10NBR (MAHLE / Filtration Group) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 9327448 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 9327448 (PUROLATOR) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 9801415UM page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 9801415UM (TRIBOGUARD) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ ABZFEH0040101XMB page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists ABZFE-H0040-10-1X/M-B (EPE / Bosch-Rexroth Filtration) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ FFKPVL17101A10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists FFKPVL17101A10 (FINNFILTER) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ HF30529 | Fleetguard | partial | Fleetguard's online catalog lists SP024F10B as an interchange for HF30529. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting. |
| ↔ HF7509 | Fleetguard | partial | Fleetguard's online catalog lists SP024F10B as an interchange for HF7509. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ HL307107 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists Hl 3.07107 (FBN) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HP81L415MB page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists HP81L4-15MB (HY-PRO) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ PL1501A010AHP01 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists PL1501A010AHP01 (MP-FILTRI) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ R900229781 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists R900229781 (EPE / Bosch-Rexroth Filtration) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ R928017038 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists R 928017038 (EPE / Bosch-Rexroth Filtration) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ SBF-9801-4Z10B | Schroeder Industries | partial | Schroeder online cross-reference (STAUFF); envelope match — verify grade and seals. |
|
↔ STU195 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists STU-195 (NORMAN) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ US1501A012AHP01 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists US1501A012AHP01 (MP-FILTRI) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ US1501A12AHP01 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists US1501A12AHP01 (MP-FILTRI) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ V6014B1C10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists V6014B1C10 (VICKERS) as replaced by SP-024-F-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the SP-024-F-10-B model number is decoded
- SP-024-F-10-BSTAUFF replacement element part number per the STAUFF Filter Interchange database.
Typical equipment & applications
- Replacement element for OEM hydraulic filter housings
Selection pitfalls — read before you substitute
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What are the dimensions of the SP-024-F-10-B filter element?
What replaces the SP-024-F-10-B filter element?
How do I read the SP-024-F-10-B part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Same-envelope elements from other brands
View full interchange →These 40 catalog element(s) share the 50×115 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.