STAUFF · Replacement Elements · inline line
SP-070-F-03-B filter element: specifications & equivalents
The SP-070-F-03-B is a STAUFF inline-line hydraulic filter element, sized 80 × 207 mm OD × length (ID 43.5 mm). Verify against the current manufacturer data sheet before ordering.
Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | inline line |
| Outside diameter OD | 80 mm |
| Inside diameter ID | 43.5 mm |
| Length | 207 mm |
| End caps | open-ended cartridge element |
| Integral bypass valve | none (housing/valve-dependent) |
| Source catalog | STAUFF: STAUFF Filter Interchange online database (filterinterchange.com) |
| Last verified | 2026-09-28 |
Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.
STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.
Dimensions & series range
| Outside diameter | 80 mm (3.150 in) |
| Inside diameter | 43.5 mm (1.713 in) |
| Overall length | 207 mm (8.150 in) |
All 80×207 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
|
↔ 02060779 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 02060779 (HYDAC) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 1269953 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 1269953 (HYDAC) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 30011965 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 30011965 (BATTENFELD) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ 57847 | WIX Filters | partial | STAUFF Filter Interchange lists 57847 (WIX) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 77783566 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 77783566 (COMEX / Ecoparts) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 7783566 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 778.356.6 (MAHLE / Filtration Group) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ 8TZX3 | Schroeder Industries | partial | Schroeder online cross-reference (STAUFF); envelope match — verify grade and seals. |
|
↔ 927176 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 927176 (PARKER) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ 927176Q | Parker | partial | STAUFF Filter Interchange lists 927176Q (PARKER) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 9314807 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 9314807 (PUROLATOR) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 9314808 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 9314808 (PUROLATOR) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ CH802FT2 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists CH 802FT2 (MODINA (SOFIMA)) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ CH802FT21 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists CH802FT21 (SOFIMA) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ D141G03B page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists D141G03B (FILTREC) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ FFKPVL17006A3 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists FFKPVL17006A3 (FINNFILTER) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ FFKPVL17006A3ABS page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists FFKPVL17006A3ABS (FINNFILTER) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ G03463 page in verification queue | Parker | partial | STAUFF Filter Interchange lists G03463 (PARKER) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ H96013003BH page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists H 9601/3-003BH (HYDAC) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HC9601FHP8H page in verification queue | Pall | partial | STAUFF Filter Interchange lists HC 9601 FHP 8H (PALL) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ HF30002 | Fleetguard | partial | STAUFF Filter Interchange lists HF30002 (FLEETGUARD / CUMMINS) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ HF30002 | Fleetguard | partial | Fleetguard's online catalog lists SP070F03B as an interchange for HF30002. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ P9601D08H2003 page in verification queue | Donaldson | partial | STAUFF Filter Interchange lists P9601D08H2003 (COMEX / Ecoparts) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ P9601D08H3 page in verification queue | Donaldson | partial | STAUFF Filter Interchange lists P9601D08H3 (COMEX / Ecoparts) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ PL1102A003AHP01 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists PL1102A003AHP01 (MP-FILTRI) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ R928016977 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists R 928016977 (EPE / Bosch-Rexroth Filtration) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ R928035038 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists R 928035038 (EPE / Bosch-Rexroth Filtration) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ R961H0803A page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists R961-H-0803A (FAIREY ARLON) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ SBF-9601-8Z1B | Schroeder Industries | partial | Schroeder online cross-reference (STAUFF); envelope match — verify grade and seals. |
| ↔ SBF-9601-8Z3B | Schroeder Industries | partial | Schroeder online cross-reference (STAUFF); envelope match — verify grade and seals. |
|
↔ STU180 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists STU-180 (NORMAN) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ US1102A003AHP01 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists US1102A003AHP01 (MP-FILTRI) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ US1102A03AHP01 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists US1102A03AHP01 (MP-FILTRI) as replaced by SP-070-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the SP-070-F-03-B model number is decoded
- SP-070-F-03-BSTAUFF replacement element part number per the STAUFF Filter Interchange database.
Typical equipment & applications
- Replacement element for OEM hydraulic filter housings
Selection pitfalls — read before you substitute
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What are the dimensions of the SP-070-F-03-B filter element?
What replaces the SP-070-F-03-B filter element?
How do I read the SP-070-F-03-B part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Same-envelope elements from other brands
View full interchange →These 15 catalog element(s) share the 80×207 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Replacement Elements series
All 4930 →Reviewed & verified by the ElementRef engineering desk against STAUFF on 2026-09-28. Read our editorial & correction policy.