ARGO-HYTOS · Hydraulic Filters · return line
E 072-786 filter element: specifications & equivalents
The E 072-786 is a ARGO-HYTOS return-line hydraulic filter element, rated at 10 µm class. Verify against the current manufacturer data sheet before ordering.
Nominal pressure, bypass setting and rated flow are taken from the ARGO-HYTOS product portal. Verify port configuration and element compatibility against the current ARGO-HYTOS data sheet before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | return line |
| Filtration rating | 10 µm |
| Rating basis | nominal |
| Rated flow | 50 L/min |
| Integral bypass valve | none (housing/valve-dependent) |
| Mass | 546 g |
| Manufacturer part no. | 15016100 |
| Source catalog | ARGO-HYTOS: ARGO-HYTOS product portal (portal.argo-hytos.com) |
| Last verified | 2026-09-28 |
Sources: ARGO-HYTOS — ARGO-HYTOS product portal (portal.argo-hytos.com) — accessed 2026-09-28.
ARGO-HYTOS® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized ARGO-HYTOS distributor.
Cross references & equivalents
No catalog-verified cross references yet. This model is in the manual verification queue — request a verified equivalent.
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the E 072-786 model number is decoded
- E 072-786ARGO-HYTOS return filter assembly part number (Return Filter) per the official product portal.
- 10 µmPublished filter fineness (nominal rating as printed by ARGO-HYTOS).
- 50 l/minRated flow of the filter assembly.
- V3.0520-56Replacement filter element for this assembly.
Typical equipment & applications
- Tank-top and in-line return filtration
- Hydraulic power units and mobile machinery
Selection pitfalls — read before you substitute
- A return-line element is not a pressure-line element: return cartridges (BN4HC low-collapse) tolerate roughly 20 bar differential, while BH4HC pressure executions are rated to 210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
- This element has no integral bypass — opening pressure is set by the housing’s reusable bypass valve. Confirm the valve setting (commonly 3.4 bar) is present before fitting.
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What micron rating does E 072-786 use?
What replaces the E 072-786 filter element?
How do I read the E 072-786 part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Other models in the Hydraulic Filters series
All 767 →Reviewed & verified by the ElementRef engineering desk against ARGO-HYTOS on 2026-09-28. Read our editorial & correction policy.