Baldwin Filters · Form 561 Interchange · inline line

PT8962-MPG filter element: specifications & equivalents

The PT8962-MPG is a Baldwin Filters inline-line hydraulic filter element. Verify against the current manufacturer data sheet before ordering.

Line type inline
Partially verified. Fit and grade trace to an official interchange document; dimensional values are compiled from 0 aftermarket listing(s) and must be confirmed against the manufacturer housing drawing. Confidence score 0.80.

Form 561 is a cross-reference only — Baldwin prints no dimensions, micron rating, collapse pressure or seal data for this part number here. Verify every specification against the current Baldwin data sheet before ordering.

Specification table

ParameterValue
Filter type inline line
Integral bypass valve none (housing/valve-dependent)
Manufacturer part no. PT8962-MPG
Source catalog Baldwin Filters: Baldwin Filters Form 561
Last verified2026-09-30

Sources: Baldwin Filters — Baldwin Filters Form 561 — accessed 2026-09-30.

Baldwin Filters® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Baldwin Filters distributor.

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ 20060D10VG30HCEP
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 20060D10VG30HCEP (INTERNORMEN) as replaced by Baldwin PT8962-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 60DO10BN3HC
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 60DO10BN3HC (HYDAC) as replaced by Baldwin PT8962-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ DHD60G10B
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists DHD60G10B (FILTREC) as replaced by Baldwin PT8962-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ FISH75201
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists FISH75201 (HIFI/JURA FILTRATION) as replaced by Baldwin PT8962-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ FISH84008
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists FISH84008 (HIFI/JURA FILTRATION) as replaced by Baldwin PT8962-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ H60D010BN
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists H60D010BN (HYDAC) as replaced by Baldwin PT8962-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ H60D010BN3HC
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists H60D010BN3HC (HYDAC) as replaced by Baldwin PT8962-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HD56MANN-FILTERpartialMANN-FILTER's online catalog lists PT8962-MPG (BALDWIN) as a comparison number for HD56. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HF30710FleetguardpartialFleetguard's online catalog lists PT8962MPG as an interchange for HF30710. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HPO6DNL412MB
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists HPO6DNL412MB (HY-PRO) as replaced by Baldwin PT8962-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ NSE014G10B
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists NSE014G10B (STAUFF) as replaced by Baldwin PT8962-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ P60D010BN4HC
page in verification queue
DonaldsonpartialBaldwin's Form 561 Number-Finder cross-reference lists P60D010BN4HC (HYDAC) as replaced by Baldwin PT8962-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ P60D010BNHC2
page in verification queue
DonaldsonpartialBaldwin's Form 561 Number-Finder cross-reference lists P60D010BNHC2 (HYDAC) as replaced by Baldwin PT8962-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RD1250487
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RD1250487 (HYDAC) as replaced by Baldwin PT8962-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ SE014E10B
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists SE014E10B (STAUFF) as replaced by Baldwin PT8962-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ SE-014-G-10-BSTAUFFpartialSTAUFF Filter Interchange lists PT8962MPG (BALDWIN) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ T60D010BNHC
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists T60D010BNHC (HYDAC) as replaced by Baldwin PT8962-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the PT8962-MPG model number is decoded

  • PT8962-MPGBaldwin filter part number per the Form 561 Number-Finder cross-reference.

Typical equipment & applications

  • Hydraulic / transmission filtration — listed in the Baldwin Form 561 Number-Finder cross-reference.

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What replaces the PT8962-MPG filter element?
17 partial match(es) requiring parameter review
How do I read the PT8962-MPG part number?
See the designation decoder above: each segment of PT8962MPG encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the Form 561 Interchange series

All 1208 →

Reviewed & verified by the ElementRef engineering desk against Baldwin Filters on 2026-09-30. Read our editorial & correction policy.