STAUFF · Replacement Elements · inline line
SE-014-G-10-B filter element: specifications & equivalents
The SE-014-G-10-B is a STAUFF inline-line hydraulic filter element, sized 47 × 84 mm OD × length (ID 22.2 mm). Verify against the current manufacturer data sheet before ordering.
Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | inline line |
| Outside diameter OD | 47 mm |
| Inside diameter ID | 22.2 mm |
| Length | 84 mm |
| End caps | open-ended cartridge element |
| Integral bypass valve | none (housing/valve-dependent) |
| Source catalog | STAUFF: STAUFF Filter Interchange online database (filterinterchange.com) |
| Last verified | 2026-09-28 |
Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.
STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.
Dimensions & series range
| Outside diameter | 47 mm (1.850 in) |
| Inside diameter | 22.2 mm (0.874 in) |
| Overall length | 84 mm (3.307 in) |
All 47×84 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
|
↔ 0200060D10VG page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 0200060D10VG (INTERNORMEN) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 1412653 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 1412653 (O & K) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 2950505 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 2950505 (CASE) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 4835413 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 4835413 (STEINBOCK) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 77889264 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 77889264 (COMEX / Ecoparts) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 890002PS10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 890002 PS 10 (MAHLE / Filtration Group) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 890002SMX10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 890002 SMX 10 (MAHLE / Filtration Group) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 890019PS10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 890019 PS 10 (MAHLE / Filtration Group) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 890019SM10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 890019SM10 (MAHLE / Filtration Group) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 890019SMX10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 890019 SMX 10 (MAHLE / Filtration Group) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ ABZFEN0040101XMA page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists ABZFE-N0040-10-1X/M-A (EPE / Bosch-Rexroth Filtration) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ ABZFEN0040101XVA page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists ABZFEN0040-10-1XVA (EPE / Bosch-Rexroth Filtration) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ DE0602B1C10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists DE0602B1C10 (DENISON) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ FFKPVL1720110 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists FFKPVL1720110 (FINNFILTER) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ FFKPVL1720110ABS page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists FFKPVL1720110ABS (FINNFILTER) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ G03058 page in verification queue | Parker | partial | STAUFF Filter Interchange lists G03058 (PARKER) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ HF30187 | Fleetguard | partial | Fleetguard's online catalog lists SE014G10B as an interchange for HF30187. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting. |
| ↔ HF6864 | Fleetguard | partial | Fleetguard's online catalog lists SE014G10B as an interchange for HF6864. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ HP06DNL412MB page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists HP06DNL4-12MB (HY-PRO) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HP06DNL412MSB page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists HP06DNL4-12MSB (HY-PRO) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HY13024 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists HY 13024 (SF-FILTER) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ MP9206 page in verification queue | MP Filtri | partial | STAUFF Filter Interchange lists MP9206 (MP-FILTRI) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ PT8962-MPG | Baldwin Filters | partial | STAUFF Filter Interchange lists PT8962MPG (BALDWIN) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ QH060DA12B page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists QH060DA12B (QUALITY FILTRATION) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ R3050906 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists R3.0509-06 (ARGO) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ R900229750 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists R900229750 (EPE / Bosch-Rexroth Filtration) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ R901052954 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists R 901052954 (EPE / Bosch-Rexroth Filtration) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ R928017777 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists R928017777 (EPE / Bosch-Rexroth Filtration) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ SBF-0060D-Z10B | Schroeder Industries | partial | Schroeder online cross-reference (STAUFF); envelope match — verify grade and seals. |
|
↔ SH75004 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists SH 75004 (HIFI / JURA Filtration) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ ST1221 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists ST1221 (ST-FILTER) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ STU614 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists STU-614 (NORMAN) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ V0602B1C10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists V0602B1C10 (VICKERS) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ V2950505 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists V2950505 (CASE) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ WGHH60010DB page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists WGHH 60010DB (WOODGATE) as replaced by SE-014-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the SE-014-G-10-B model number is decoded
- SE-014-G-10-BSTAUFF replacement element part number per the STAUFF Filter Interchange database.
Typical equipment & applications
- Replacement element for OEM hydraulic filter housings
Selection pitfalls — read before you substitute
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What are the dimensions of the SE-014-G-10-B filter element?
What replaces the SE-014-G-10-B filter element?
How do I read the SE-014-G-10-B part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Same-envelope elements from other brands
View full interchange →These 31 catalog element(s) share the 47×84 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Replacement Elements series
All 4930 →Reviewed & verified by the ElementRef engineering desk against STAUFF on 2026-09-28. Read our editorial & correction policy.