STAUFF · Replacement Elements · inline line
RE-090-G-10-B filter element: specifications & equivalents
The RE-090-G-10-B is a STAUFF inline-line hydraulic filter element, sized 95 × 195 mm OD × length (ID 48.5 mm). Verify against the current manufacturer data sheet before ordering.
Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | inline line |
| Outside diameter OD | 95 mm |
| Inside diameter ID | 48.5 mm |
| Length | 195 mm |
| End caps | open-ended cartridge element |
| Integral bypass valve | none (housing/valve-dependent) |
| Source catalog | STAUFF: STAUFF Filter Interchange online database (filterinterchange.com) |
| Last verified | 2026-09-28 |
Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.
STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.
Dimensions & series range
| Outside diameter | 95 mm (3.740 in) |
| Inside diameter | 48.5 mm (1.909 in) |
| Overall length | 195 mm (7.677 in) |
All 95×195 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
|
↔ 1262993 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 1262993 (HYDAC) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 1263597 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 1263597 (HYDAC) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 1263993 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 1263993 (HYDAC) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 1266474 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 1266474 (HYDAC) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 300427 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 300427 (INTERNORMEN) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 32916900 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 32916900 (JCB) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 890015PS10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 890015 PS 10 (MAHLE / Filtration Group) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 890015SM10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 890015SM10 (MAHLE / Filtration Group) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 890015SMX10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 890015 SMX 10 (MAHLE / Filtration Group) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 890045PS10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 890045PS10 (MAHLE / Filtration Group) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 890045PS10NBR page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 890045PS10NBR (MAHLE / Filtration Group) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 890045SMX10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 890045SMX10 (MAHLE / Filtration Group) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 890045SMX10NBR page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 890045SMX10NBR (MAHLE / Filtration Group) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ B9203860 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists B9203860 (GRIMME) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ E30TR330H10LLLA page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists E30TR330H10LLLA (EPE / Bosch-Rexroth Filtration) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ ER332B2C10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists ER332B2C10 (WESTERN) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ G03309 page in verification queue | Parker | partial | STAUFF Filter Interchange lists G03309 (PARKER) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ HF6892 | Fleetguard | partial | Fleetguard's online catalog lists RE090G10B as an interchange for HF6892. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ HY13215 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists HY 13215 (SF-FILTER) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ PT23061-MPG | Baldwin Filters | partial | Baldwin's Form 561 Number-Finder cross-reference lists RE090G10B (STAUFF) as replaced by Baldwin PT23061-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ QH330RA12B page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists QH330RA12B (QUALITY FILTRATION) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ RE-090-G-10-B | STAUFF | partial | STAUFF Filter Interchange lists RE-090-G-10-B (STAUFF) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ SBF-0330R-Z10B | Schroeder Industries | partial | Schroeder online cross-reference (STAUFF); envelope match — verify grade and seals. |
|
↔ ST1265 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists ST1265 (ST-FILTER) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ STU647 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists STU-647 (NORMAN) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ V0332RB2C10 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists V0332RB2C10 (VICKERS) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ Y104000T page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists Y104000T (MECALAC) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ Y104000T0000 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists Y104000T0000 (MECALAC) as replaced by RE-090-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the RE-090-G-10-B model number is decoded
- RE-090-G-10-BSTAUFF replacement element part number per the STAUFF Filter Interchange database.
Typical equipment & applications
- Replacement element for OEM hydraulic filter housings
Selection pitfalls — read before you substitute
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What are the dimensions of the RE-090-G-10-B filter element?
What replaces the RE-090-G-10-B filter element?
How do I read the RE-090-G-10-B part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Same-envelope elements from other brands
View full interchange →These 93 catalog element(s) share the 95×195 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Replacement Elements series
All 4930 →Reviewed & verified by the ElementRef engineering desk against STAUFF on 2026-09-28. Read our editorial & correction policy.